Thruster: Thrust vs RPM
Thruster: Thrust vs Input Power
Thruster: Input Power vs RPM
Winding: Voltage RMS (line-to-line) vs RPM
Winding: Voltage Peak (line-to-line) vs RPM
Winding: Current vs RPM
Winding: Thrust vs Current
Reading these curves
The current curve is the current that produces torque. A drive also supplies a current component that produces none, so the total current at the motor is higher than shown by an amount that depends on how your drive is configured. Size on current, and allow for that.
The input power on the thruster charts is a separate measurement: the active power drawn at the drive input, motor and drive losses included.
Not sure about your configuration?
Get a quote for the model anyway and we will help you find the right winding.
Tool Overview & Disclaimer
Compare thruster models across speed, thrust, RPM, and input power for your operating envelope.
Pick a target performance point and system voltage to get winding recommendations, plus detailed electrical curves for each option.
Disclaimer: these results are for early-stage sizing only: validate with detailed engineering, controller/VFD matching, and system-level testing before final design decisions. Simulated forward-speed values assume ideal flow and typically read higher than real-world measurements, which is why some low-speed figures can exceed the Bollard Thrust values.
Bollard thrust (0 m/s) is measured on a physical unit. Forward-speed thrust is derived from CFD anchored to those measurements, and electrical power is a fitted curve through measured VFD input power. All figures are indicative estimates for comparison and sizing, not a guaranteed or warranted specification. See the Methodology & Limitations page for the full breakdown.
Pick a winding to get a price
Click a point on any graph, then choose one of the
suggested windings. We attach it to your request so you do
not have to type it.
Ready for a price on
this configuration?
We attach everything above to your request. You only fill in
what the graph cannot tell us.
You will hear from us within two working days.
Not sure about your configuration? Get a quote for the model anyway and we will help you find the right winding.
Step 2 of 3
Request quotation
Your selection is attached automatically. We only need the details we cannot read from the graph.
Your configuration
Measured test data
Model
VL
Symmetric
Configuration
Outlet/Outlet
Winding
32 turns
400 V AC
Operating point
1,800 RPM
Bollard Thrust
Thrust
965.0 N (216.9 lbf)
Input power
9.5 kW