Thruster Selector Methodology & Limitations

Performance data for the Copenhagen Subsea Thruster Selector

Back to Thruster Selector
About these figures. Bollard thrust (0 m/s) is measured on physical units. Thrust at forward speed is derived from CFD simulation anchored to those measurements. Electrical power is a fitted curve through measured VFD input power, scaled to forward speed using CFD shaft-power ratios. All figures are indicative engineering estimates for comparison and sizing; they are not guaranteed performance and not a warranted specification.

Scope

These figures describe axial thrust and electrical input power for the thruster in forward operation, from bollard condition (0 m/s) up to the highest inflow speed shown for each thruster size. Reverse operation is included for bollard thrust (0 m/s) only; no reverse data exists at forward inflow speeds. Each thruster size is shown in four inlet/outlet ring and housing configurations plus a dedicated AUV configuration.

Thrust

At 0 m/s (measured)

The 0 m/s figures come from forcemeter testing, smoothed with a centred three-point moving average, and averaged across both builds of each thruster size. Thrust is independent of the number of winding turns, so averaging the two builds is valid and reduces build-to-build scatter.

At forward speed (derived from CFD)

For each configuration, two simulated speeds act as anchor points, and thrust is expressed as a speed-dependent factor applied to the measured bollard thrust:

T(v, n) = T_measured(0 m/s, n) × f(v, n), f = 1 − c/n − d/n²

The anchor points are the raw, unmodified CFD results; they have not been rescaled or calibrated to the measurements. This is deliberate: it means the CFD reports can be supplied unmodified alongside these figures, and any reader can trace a number back to the run it came from. The consequence is that at the lowest inflow speed the factor can slightly exceed 1: the model shows marginally more thrust at 0.5 m/s than at bollard. That is a property of an idealised simulation, not a measurement, and should be read as such.

Net axial force

The thrust at speed is the total axial force on the complete assembly: propeller thrust minus the hydrodynamic drag of the thruster body in that inflow. It is not propeller-only thrust.

AUV configuration (simulation only)

No physical unit of the AUV configuration has been tested. Both thrust and power for those configurations are pure CFD, with no measured anchor of any kind.

Electrical Power

At 0 m/s (fitted curve)

The underlying data is measured active input power at the drive (VFD), logged during the same test runs as the thrust. For each configuration a least-squares cubic through the origin is fitted to that measured power against set speed:

P(n) = p₃n³ + p₂n² + p₁n

The published figure is that curve evaluated at each speed. The fit is smooth, monotonic and goes to zero at zero speed, which is what a selection tool needs. The cost is that forcing the curve through the origin removes fixed no-load consumption (magnetising, iron and friction losses plus the drive's own draw), which a real drive does consume. Above roughly half rated speed the fit and the measurement agree within a few percent; at the very bottom of each speed range the fit can differ substantially (see Limitations, item 3).

At forward speed (CFD shaft-power ratio)

P(v, n) = P(0 m/s, n) × h(v/n)

where h is the ratio of simulated shaft power at inflow speed v to simulated shaft power at bollard, at the same rotational speed. Because h is a ratio taken at a fixed rotational speed, drivetrain and motor efficiency cancel out: no efficiency figure is assumed anywhere in this dataset. The physical basis (P/n³ constant at fixed advance ratio) was verified against five to six simulated speeds per configuration, with a spread of 0.3 % to 6.1 %. Every power figure at speed is an interpolation between simulated points; nothing is extrapolated.

Motor voltage

The motor voltage in the winding curves is measured: the line-to-line RMS voltage logged at the drive output during the same test runs as the thrust, fitted against speed for the winding each unit was built with, then scaled by turns — voltage is proportional to the number of turns. Every point lies inside the speed range that was tested, and the curves hold to about 1 % against the logged values.

The figures are line-to-line, so apparent power is √3 · I · V.

Limitations

  1. Power at speed is biased low. h is a shaft power ratio applied to electrical power. When hydrodynamic load drops with inflow, electrical power falls by less than shaft power does, because fixed losses are unchanged at the same rotational speed. The method therefore understates electrical power at forward speed, typically a few percent, up to around 10 % at the low end of the speed range. Size drives and supplies with headroom accordingly.
  2. One configuration shows more shaft power at speed than at bollard. In the compact asymmetric forward configuration of the smallest thruster size, the simulated shaft-power ratio sits above 1 across the whole low speed range (1.02–1.06). This is a systematic property of that CFD setup, not scatter. Treat that configuration's power at speed as the least certain in the set.
  3. The two lowest speed points of the largest thruster size (VXL) are unreliable in power. A cubic through the origin cannot follow measured power at very low load, where fixed losses dominate. At the lowest speed the fit deviates from the measured point by up to +140 % in one configuration and −53 % in another. Do not use the bottom of the VXL power curve for sizing; contact us for the raw measured points.
  4. A few cells show negative power. At the lowest rotational speeds combined with the highest inflow, the propeller windmills. For AUV configurations this is physically correct (shaft power). For a small number of measurement-derived cells the negative sign is an artefact: read those as "approximately zero plus fixed losses". The largest such value is −0.06 kW.
  5. Test conditions affect results. Performance in the field will differ where conditions differ, in particular with tunnel or hull interaction, fouling, off-design inflow angles, water temperature and viscosity, supply voltage variation, submergence depth, and VFD characteristics. The test conditions used to obtain these figures are available on request alongside the full test reports.

Not Covered by This Dataset

  • Reverse thrust and reverse power at forward inflow speed
  • Inflow at an angle to the thruster axis
  • Transient and dynamic performance: acceleration, reversals, step response
  • Cavitation limits and cavitation-induced thrust breakdown
  • Noise and vibration
  • Thermal limits and continuous-duty derating
  • Windings other than the one stated

Status & Traceability

Every figure in the Thruster Selector is traceable to either a specific test run or a specific CFD run. The simulation set behind the speed-dependent figures comprises 429 individual CFD runs. Full test reports and the unmodified CFD reports are available on request.

Winding Suggestion Tool

Once you have identified a suitable operating point on the performance charts, the winding selector helps you find a compatible motor winding for your system voltage.

How to use it

  1. Select your system voltage and whether your supply is AC or DC. AC uses the RMS voltage; DC uses the peak voltage.
  2. Click a point on any of the three performance charts. The tool snaps to the nearest curve and records the operating point: the RPM, thrust, and input power at that point.
  3. Review the suggested windings. Up to three candidates are shown, ranked by how well they use your available voltage. Click any suggestion to open its detailed electrical performance curves.
  4. Click Get quote if the winding fits your application. This opens the quote form and passes your selected model, winding and operating point to it.

How suggestions are ranked

Each winding has a characteristic voltage that rises with motor RPM. The tool finds the winding RPM in the reference table that meets or just exceeds your selected operating RPM, then compares the winding's voltage at that RPM to your system voltage.

Windings whose voltage at the required RPM stays within your system voltage are preferred. Among those, the one that uses the available voltage most fully is ranked first. Two neighbouring candidates (one turn count above, one below) are also shown so you can compare the trade-off between voltage headroom and current draw.

AC vs DC

The AC / DC toggle sets which voltage the winding comparison uses: Vrms in AC mode, Vpeak in DC mode. Set it before selecting your operating point.

Winding curves

Clicking a suggested winding opens three curves: voltage vs RPM (RMS in AC mode, peak in DC mode), current vs RPM, and thrust vs current. These curves are drawn from measured winding reference data taken at bollard thrust conditions. The motor's electrical behaviour (voltage and current at a given RPM) does not change with inflow speed, so these curves apply equally whether you selected your operating point on the bollard chart or on a forward-speed chart. The operating point marker shows where your selected RPM falls on each curve.

Because bollard is the highest-load condition at a given RPM, the current shown on these curves is the highest expected current draw at that RPM. Once the vessel is moving at speed, the propeller sees inflow and needs less torque to reach the same RPM, so actual current draw will be lower than the bollard value shown here. Treat the winding current curves as a conservative, worst-case reference for sizing, not a prediction of current at speed.

Three series are shown per curve: Sym (symmetrical propeller, solid line), Asym Fwd (asymmetric propeller, forward direction, dashed), and Asym Rev (asymmetric propeller, reverse direction, dotted). The curves reflect the different torque and thrust loading on the motor for each propeller type.

Drive sizing guide

The current does not fall to zero as load drops — there is a floor of a few amps that the drive supplies regardless, so at low RPM the total is several times the torque current, while near the top of the range it is within a few percent to a few tens of percent of it.

  1. Current sets the drive selection. Read it at the highest RPM you will run, in the propeller configuration and direction you will run it, add your drive's figure for the non-torque component, and compare the total against the drive's continuous output current rating with margin.
  2. Voltage sets the drive's output requirement. The curve is line-to-line RMS; peak line-to-line is √2 times that, and it is the DC bus the drive needs to synthesise it. The AC / DC toggle selects whichever applies to your supply.
  3. Input power gives supply capacity and cooling load, from the thruster charts. A drive's kW rating carries an assumed power factor, so current remains the selection criterion.
  4. Cable voltage drop between supply and drive is additional to these figures.

We would rather send you the raw measured points than have you work back to them from these curves. Ask, and we will.

What the tool does not do

  • It does not account for voltage drop in the cable between the supply and the drive. Apply appropriate derating for your cable length and cross-section.
  • It does not select a VFD; the VFD must be matched separately to the winding current and switching frequency requirements.
  • It does not account for inrush current at start-up or during rapid speed changes.
  • The suggestion is based on steady-state electrical performance at the selected RPM, not on a full thermal or efficiency analysis.

Thruster Sizes & Dimensions

The drawing below shows the outer dimensions of all four sizes side by side.

VS, VM, VL, and VXL thruster sizes with outer diameters and overall height/width, in millimeters

Click to open full resolution. All dimensions are in millimeters (mm).

Not a warranty. Nothing here constitutes a guaranteed performance specification or a contractual commitment. For a guaranteed figure for a specific application, contact Copenhagen Subsea at sales@copenhagensubsea.com.